Products | Offshore/marine coated sensors ..Cos-..-CT / ..-OCT
Offshore/marine coated sensors for Ex or safe areas
Seawater resistant, some parts in stainless steel / nickel-plated
Measurements in mm
Description – Offshore/marine coated (Seawater resistant) sensors ..Cos-P..-CT
- ExCos-P..-CT, RedCos-P..-CT and InCos-P..-CT are pressure, differential pressure or VAV-control sensors with an excellent resistance to chemicals and sea water
- Aluminium housing offshore/marine coated, seawater resistant
- Sensor connection and cable glands Ex-e approved, nickel-plated,
screws in stainless steel 316L
Technical data
Measurement range*Min. range*Overload protected*Electric supplyCable glandsCable entryOutputDisplayProtection / Housing materialAmbient temperature/-humidityPower supplyWeightExCos-P..-CT / RedCos-P..-CT for allInstallation of ExCos-P..-CTInstallation of RedCos-P..-CTInstallation of InCos-P..-CT*depending on type..Cos-P..-CT
± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DCM16 × 1,5 / Ex-e approved, nickel-platedØ 5...10 mm0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium, offshore/marine coated-20°...+50°C, 0...95 %rHover integrated terminal box~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22Zone 2, 22Safe area (industrial applications)Delivery – ..Cos-P..-CT
- Offshore/marine coated, seawater resistant sensor ..Cos-P..-CT with integrated Ex-e terminal box
- 3 × Tapping screw in stainless steel Ø 4,2 × 13 mm
- 1 × Short circuit tube ca. 140 mm length
Special model – ..Cos-P..-A-CT
- Offshore/marine coated, seawater resistant, module with one intrinsically 4..20 mA output to connect external actual value indicator
Accessories – ..Cos-P..-CT
- Intrinsic, external LCD indicator connectable to ..Cos-P..-A-CT sensors
- Mounting bracket for round air ducts up to Ø 600 mm
- Installation kit with 2 m flexible pressure hose Ø 6 mm
- Stainless steel pressure tube connection for 6 mm clamp fittings
- M16 standard cable glands in brass nickel plated
- M20 Ex-d cable glands in brass nickel plated for armoured cables
(Offshore applications)
Measurements in mm
Variations of clamping ring connections in stainless steel
optionally available
Description – Offshore/marine coated (Seawater resistant) version ..Cos-P..-OCT
- ExCos-P..-OCT, RedCos-P..-OCT and InCos-P..-OCT are pressure, differential pressure or VAV-control sensors with an excellent resistance
to chemicals and sea water for Offshore applications - Aluminium housing offshore/marine coated, seawater resistant
- Cable glands Ex-e approved, nickel-plated, tubes for clamping ring
Ø 6 mm and screws in stainless steel 316L
Technical data
Measurement range*Min. range*Overload protected*Electric supplyCable glandsCable entryOutputDisplayProtection / Housing materialAmbient temperature/-humidityPower supplyWeightExCos-P..-OCT / RedCos-P..-OCT for allInstallation of ExCos-P..-OCTInstallation of RedCos-P..-OCTInstallation of InCos-P..-OCT*depending on type..Cos-P..-OCT
± 100 Pa...± 7.500 Pa20 Pa25.000 Pa...120.000 Pa24 VAC / DCM20 × 1,5 / Ex-e approved, nickel-platedØ 6...13 mm0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium, offshore/marine coated-20°...+50°C, 0...95 %rHover integrated terminal box~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22Zone 2, 22Safe area (industrial applications)Delivery – ..Cos-P..-OCT
- Offshore/marine coated, seawater resistant, sensor (Offshore version) ..Cos-P..-OCT with integrated Ex-e terminal box
- 3 × Tapping screw in stainless steel Ø 4,2 × 13 mm
- 1 × Short circuit tube ca. 250 mm length
Special model – ..Cos-P..-A-OCT
- Offshore/marine coated, seawater resistant, offshore module with one intrinsically 4..20 mA output to connect external actual value indicator
Accessories – ..Cos-P..-OCT
- Intrinsic, external LCD indicator connectable to ..Cos-P..-A-OCT sensors
- Mounting bracket for round air ducts up to Ø 600 mm
- Installation kit with 2 m flexible pressure hose Ø 6 mm
- Stainless steel pressure tube connection for 6 mm clamp fittings
- M16 standard cable glands in brass nickel plated
- M20 Ex-d cable glands in brass nickel plated for armoured cables
(Offshore applications)
Description – Offshore/marine coated (Seawater resistant) modules ..Cos-D-CT
- ExCos-D-CT, RedCos-D-CT and InCos-D-CT transmitter together with ExPro-C../InPro-C.. sensors are for temperature and/or humidity measurement in HVAC systems with an excellent resistance against chemicals and sea water atmosphere
- Aluminium housing offshore/marine coated, seawater resistant
- Cable glands Ex-e approved, nickel-plated, screws in stainless steel 316L
Technical data
Measurement range Temperature*Measurement range Humidity*ApplicationElectric supplyCable glandsCable entryConnectable sensorOutputDisplayHousing material / protectionAmbient temperature/-humidityPower supplyWeightExCos-D-CT / RedCos-D-CT for allInstallation of ExCos-D-CTInstallation of RedCos-D-CTInstallation of InCos-D-CT*depending on sensor type..Cos-D-CT
-40 °C...+125 °C0...100 %rHRoom- and / or Duct-measurement24 VAC / DCM16 × 1,5 / Ex-e approved, nickel-platedØ 5...10 mm1 × ExPro-C.. (InPro-C.. by InCos-D-CT)0-10 V DC, (0)4-20 mA, selectable on siteBacklight, defeatableIP66 / Aluminium, offshore/marine coated-20°...+50°C, 0...95 %rHover integrated terminal box~ 1,1 kgGases, mists, vapours, dustZone 1, 2, 21, 22Zone 2, 22Safe area (industrial applications)Delivery – ..Cos-D-CT
- Offshore/marine coated, seawater resistant module ..Cos-D-CT with integrated Ex-e terminal box
- 3 × Tapping screw in stainless steel Ø 4,2 × 13 mm
- Required accessory: ExPro-C.. sensor, InPro-C.. for InCos-D-CT
Accessories – ..Cos-D-CT
- ExPro-C.. sensors for ExCos-D/RedCos-D transmitter,
InPro-C.. sensors for InCos-D transmitter - Mounting bracket for round air ducts up to Ø 600 mm
- Sensor extension cable 3 m
- M16 standard cable glands in brass nickel plated
- M20 Ex-d cable glands in brass nickel plated for armoured cables
(Offshore applications)